Profile
Back to NewsBack
GitHub Trending 2 min
Reader Mode
sourceperl/pyModbusTCP: A simple Modbus/TCP library for Python

sourceperl/pyModbusTCP: A simple Modbus/TCP library for Python

7 hours ago

.. |badge_tests| image:: https://github.com/sourceperl/pyModbusTCP/actions/workflows/tests.yml/badge.svg?branch=master :target: https://github.com/sourceperl/pyModbusTCP/actions/workflows/tests.yml

.. |badge_docs| image:: https://readthedocs.org/projects/pymodbustcp/badge/?version=latest :target: http://pymodbustcp.readthedocs.io/

pyModbusTCP |badge_tests| |badge_docs| ======================================

A simple Modbus/TCP client library for Python. pyModbusTCP is pure Python code without any extension or external module dependency.

Since version 0.1.0, a server is also available.

Tests -----

The module is currently test on Python 3.10, 3.11, 3.12, 3.13 and 3.14.

For Linux, Mac OS and Windows.

Documentation -------------

Documentation of the last release is available online at https://pymodbustcp.readthedocs.io/.

Setup -----

You can install this package from:

PyPI, the easy way:

.. code-block:: bash

# install the last available release (stable) sudo pip install pyModbusTCP

.. code-block:: bash

# install a specific version (here release v0.1.10) sudo pip install pyModbusTCP==v0.1.10

From GitHub:

.. code-block:: bash

# install a specific version (here release v0.1.10) directly from github servers sudo pip install git+https://github.com/sourceperl/[email protected]

Note on the use of versions:

Over time, some things can change. So, it's a good practice that you always use a specific version of a package for your project, instead of just relying on the default behavior. Without precision, the installation tools will always install the latest version available for a package, this may have some drawbacks. For example, in pyModbusTCP, the TCP automatic open mode will be active by default from version 0.2.0. It is not the case with previous versions and it just doesn't exist before the 0.0.12. This can lead to some strange behaviour of your application if you are not aware of the change. Look at CHANGES _ for details on versions available.

Usage example -------------

See examples/ for full scripts.

include (for all samples) ~~~~~~~~~~~~~~~~~~~~~~~~~

.. code-block:: python

from pyModbusTCP.client import ModbusClient

module init (TCP always open) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.. code-block:: python

# TCP auto connect on first modbus request c = ModbusClient(host="localhost", port=502, unit_id=1, auto_open=True)

module init (TCP open/close for each request) ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.. code-block:: python

# TCP auto connect on modbus request, close after it c = ModbusClient(host="127.0.0.1", auto_open=True, auto_close=True)

Read 2x 16 bits registers at modbus address 0 : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.. code-block:: python

regs = c.read_holding_registers(0, 2)

if regs: print(regs) else: print("read error")

Write value 44 and 55 to registers at modbus address 10 : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.. code-block:: python

if c.write_multiple_registers(10, [44,55]): print("write ok") else: print("write error")

Chat with me